4112 Evan Brooks Dr. Baton Rouge, LA 70814

Call Us Today! 225.303.0007

Explosion Proof Industrial Grade HVAC/R and Pressurization Systems
Offering the Keys to Success:
Quality, Pricing, and On Time Delivery
explosion proof hvac/r systems offshore platforms
International Offices
explosion proof hvac/r systems petrochemical
International Offices

Rooftop Units

Offering both Fully Custom and Standard Products that are Tested for Operational Performance and Certified for Hazardous Duty Operation in Industrial and Offshore applications.

Safe Air Technology offers a variety of Explosion Proof Rooftop Units. These systems range from modified commercial grade systems to fully custom designs with capacities ranging from 1 to 3 Tons with many options available.

These Severe Duty systems are designed by our professional engineering staff and are fully documented and certified for operational performance and compliance to both NEC and IEC codes related to NFPA 70 Article 500-505 for Hazardous Environments. Let our Sales and Engineering Departments work with you to offer a system that will comply with 100% of your specifications for both classification and Severe Duty operation. We look forward to serving your needs.

Please contact Safe Air Technology if you need assistance selecting a product.

  • RT-XPC Series Roof Top Unit
RT-XPC Series Roof Top Unit
  • Division II and Zone II in Condenser and/or Evaporator
  • 13,500 and 15,000 BTU/HR Cooling Capacity
  • 60 & 50 Hertz Models
  • CSA Third Party Certified

Standard Features

  • All Electrical Components UL and/or CSA Certified
  • Explosion Proof Overload Protection on Motors and Compressors
  • Easily Accessible Motor for fast and Convenient Service
  • Non Sparking Condenser Fan and Blower designs
  • Aluminum Fin and Copper Tube Coils for Maximum Heat Transfer
  • Explosion Proof or General Purpose Operational Controls
  • Ceiling Assembly Included with Air Filter
  • Operation, Maintenance & Installation Manuals Included
  • System Third Party Certified for use in Hazardous Locations by CSA International

Available Options

  • B
    Group B Classification
  • CC
    Copper Tube and Copper Fin Coils
  • CRT
    Export Crate for Sea or Air Shipping
  • EPX
    Epoxy Coated Metal (50HZ Units Only)
  • HTR
    Electric Heater Installed
  • MG1
    Marine Grade Coating— Condenser & Evaporator Coated
  • MG2
    Marine Grade Coating— Coils & Sheet Metal Coated
  • SH4
    304 Stainless Steel Housing
  • SH6
    316 Stainless Steel Housing
  • SVI
    Service Port Installed
Notes
If an option required to meet your specification is not listed, please contact our Sales Engineering Department. We will be happy to work with you to ensure our system fully complies with your specifications. 
Quality, Pricing and On Time Delivery
  • RTXP1 Series Roof Top Unit
RTXP1 Series Roof Top Unit
  • Division 1 and Zone 1 Condenser Section, General Purpose Evaporator Section
  • 13,500 and 15,000 BTU/HR Cooling Capacity
  • Electric Heat Installed
  • 60 & 50 Hertz Models
  • CSA Third Party Certified

Standard Features

  • All Electrical Components UL and/or CSA Certified
  • Explosion Proof Overload Protection on Motors and Compressors
  • Easily Accessible Motor for fast and Convenient Service
  • Division 1 Explosion Proof Condenser Fan Motor Installed
  • Unit Housing Constructed from 304 Stainless Steel for Severe Environments
  • Non Sparking Condenser Fan and Blower designs
  • Adsil Coated Coils for Corrosion Protection in Corrosive Enviropments
  • Aluminum Fin and Copper Tube Coils for Maximum Heat Transfer
  • General Purpose Operational Controls Included
  • Ceiling Assembly Included with Air Filter
  • Operation, Maintenance & Installation Manuals Included
  • System NEC Certificate of Conformance

Available Options

  • CC
    Copper Tube and Copper Fin Coils
  • CRT
    Export Crate for Sea or Air Shipping
  • EPX
    Epoxy Coated Metal (50HZ Units Only)
  • HTR
    Electric Heater Installed
  • MG1
    Marine Grade Coating - Condenser & Evaporator Coated
  • MG2
    Marine Grade Coating - Coils & Sheet Metal Coated
  • SH6
    316 Stainless Steel Housing
  • SVI
    Service Port Installed
Notes
If an option required to meet your specification is not listed, please contact our Sales Engineering Department. We will be happy to work with you to ensure our system fully complies with your specifications. 
Quality, Pricing and On Time Delivery
  • RTXP2 Series Roof Top Unit
RTXP2 Series Roof Top Unit
  • Division I or II & Zone II or II in Condenser and/or Evaporator
  • 15,000 to 36,000 BTU/HR Cooling Capacity
  • 60 & 50 Hertz Models

Standard Features

  • All Electrical Components UL and/or CSA Certified
  • Explosion Proof Overload Protection on Motors and Compressors
  • Easily Accessible Motor for fast and Convenient Service
  • Non Sparking Condenser Fan and Blower designs
  • Aluminum Fin and Copper Tube Coils for Maximum Heat Transfer
  • Explosion Proof Operational Controls Included
  • Operation, Maintenance & Installation Manuals Included
  • System NEC Certificate of Conformance

Available Options

  • KW/XP
    Explosion Proof Electric Heat
  • KW/GP
    General Purpose Electric Heat
  • B
    Group B Classification
  • CC
    Copper Tube and Copper Fin Coils
  • CRT
    Export Crate for Sea or Air Shipping
  • EPX
    Epoxy Coated Metal (50HZ Units Only)
  • MG1
    Marine Grade Coating - Condenser & Evaporator Coated
  • MG2
    Marine Grade Coating - Coils & Sheet Metal Coated
  • SH6
    316 Stainless Steel Housing
  • SVI
    Service Port Installed
Notes
If an option required to meet your specification is not listed, please contact our Sales Engineering Department. We will be happy to work with you to ensure our system fully complies with your specifications. 
Quality, Pricing and On Time Delivery
Request a Quote
Request Drawings - RT-XPC Series Roof Top Unit
Request a Quote - RT-XPC Series Roof Top Unit
Request Drawings - RTXP1 Series Roof Top Unit
Request a Quote - RTXP1 Series Roof Top Unit
Request Drawings - RTXP2 Series Roof Top Unit
Request a Quote - RTXP2 Series Roof Top Unit
Request PDF Catalog
Catalogs are currently being updated. Please contact our sales department for information.